Back to feed
20Track

Philips Hue Bridge: Remote code execution

Philips Hue Bridge · CVE-2026-126979 ZDI-26-964
0 news outlets0 CERTs and agencies1 research labs

Assessment: Track

SSVC decision points: exploitation none, automatable no, technical impact total, deployment low.

What is it?

Philips Hue Bridge HomeKit Accessory Protocol chacha20_decrypt Integer Underflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. When parsing pairing requests, the process does not properly validate user-supplied data, which can result in an integer underflow before writing to memory. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28332.

Evidence

Technical advisories1Detailed write-ups from security research teams

Exploitation

  • Exploit code published (not verified by us)
  • Exploited in the wild (confirmed by a source)
  • Listed as known exploited (CISA KEV)
CVSS
8.8
EPSS
0.5%
First seen
5 d ago
Status
confirmed

All Philips vulnerabilities