Vulnocalypse
Back to feed
23Track

Plaintext Password Disclosure via VBScript Sensor Error Message in Paessler PRTG Network Monitor

Microsoft Windows · CVE-2026-4638
0 news outlets0 CERTs and agencies0 researchers

Assessment: Track

SSVC decision points: exploitation none, automatable no, technical impact partial, deployment high.

What is it?

PRTG Network Monitor before version 26.2.120.1449 ships a demo EXE/Script sensor that multiplies two integer parameters using cscript.exe. If a non-numeric value is passed instead, cscript.exe raises a 'Type mismatch' runtime error that includes the offending parameter value in plaintext. PRTG provides a documented placeholder variable, %windowspassword, which resolves to the configured Windows/domain password used by PRTG and can be passed as a sensor parameter.  Any PRTG user who is not restricted to read-only access and is permitted to create sensors (the default for non-read-only users) can pass %windowspassword as an argument to the demo VBScript sensor, triggering the type-mismatch error and causing PRTG to display the plaintext password in the sensor's error output.

Evidence

Technical advisories (1)
Detailed write-ups from security research teams

Exploitation

  • Public proof of concept
  • Exploited in the wild
  • Listed as known exploited
CVSS
7.1
EPSS
0.3%
First seen
1 h ago
Status
confirmed

All Microsoft vulnerabilities