Vulnocalypse
Back to feed
33impact

Siemens Siemens ICS: A vulnerability has been identified in SIMATIC IPC BX-21A (All versions < V31.01.13), SIMATIC IPC RW-543A (All versions

Siemens ICS · CVE-2026-72895
0 news outlets0 CERTs and agencies0 researchers

What is it?

A vulnerability has been identified in SIMATIC IPC BX-21A (All versions < V31.01.13), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G (All versions < V28.01.15). A BIOS vendor test key is present in the UEFI Secure Boot key database. This could allow a local attacker with physical or administrative access to the device to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled, potentially leading to a full loss of confidentiality, integrity, and availability of the device.

Evidence

No coverage recorded yet.

Exploitation

  • Public proof of concept
  • Exploited in the wild
  • Listed as known exploited
CVSS
7.7
EPSS
0.1%
First seen
8 h ago
Status
corroborated